ASPGLK-G5F11

Digital input and relay output isolator: It converts dry‑contact or NAMUR‑type proximity switch signals from the field into isolated outputs via relay contacts, which are then transmitted to the control room.
  • Commodity name: ASPGLK-G5F11
  • Input: Dry contact or NAMUR-type proximity switch
  • Number of channels: Four in, four out
  • Output: Relay contacts
  • Power supply mode (both can be centralized power supply): 24VDC

Phone:

Product Details

  • Product Description
  • Product Introduction

    Digital input and relay output isolator: It converts dry‑contact or NAMUR‑type proximity switch signals from the field into isolated relay‑output contacts, which are then transmitted to the control room. When placing an order, please specify whether the four channels of inputs and outputs are in phase or out of phase (default: in phase). This product requires an independent power supply, with three‑terminal isolation between the input, output, and power supply.

    Technical Specifications

    • Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
    • Operating power consumption: 2.0 W
    • Input signal: dry contact or NAMUR-type proximity switch
    • Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
    • Open-circuit voltage: approximately 8 V
    • Short-circuit current: approximately 8 mA
    • Output signal: relay contacts
    • Allowable load: 125 VAC / 0.5 A or 24 VDC / 1 A
    • Line fault: When the input current is ≤50 μA, a broken‑wire condition is detected and the output relay trips; when the input current is ≥6.5 mA, a short circuit is detected and the output relay trips, while the channel indicator flashes red.
    • Switch life: >100,000 cycles
    • Switching frequency: <10 Hz
    • Response time: <20ms
    • Electromagnetic Compatibility: IEC 61326-3-1
    • Dielectric strength: ≥3000 VAC (between intrinsically safe and non‑intrinsically safe sides); ≥1500 VAC (between power supply and non‑intrinsically safe side)
    • Insulation resistance: ≥100 MΩ (input/output/power supply)
    • Operating temperature: -20°C to +60°C
    • Storage temperature: -40°C to +80°C
    • Dimensions: Width 17.8 mm × Height 110 mm × Depth 117 mm

Product Introduction

Digital input and relay output isolator: It converts dry‑contact or NAMUR‑type proximity switch signals from the field into isolated relay‑output contacts, which are then transmitted to the control room. When placing an order, please specify whether the four channels of inputs and outputs are in phase or out of phase (default: in phase). This product requires an independent power supply, with three‑terminal isolation between the input, output, and power supply.

Technical Specifications

  • Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
  • Operating power consumption: 2.0 W
  • Input signal: dry contact or NAMUR-type proximity switch
  • Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
  • Open-circuit voltage: approximately 8 V
  • Short-circuit current: approximately 8 mA
  • Output signal: relay contacts
  • Allowable load: 125 VAC / 0.5 A or 24 VDC / 1 A
  • Line fault: When the input current is ≤50 μA, a broken‑wire condition is detected and the output relay trips; when the input current is ≥6.5 mA, a short circuit is detected and the output relay trips, while the channel indicator flashes red.
  • Switch life: >100,000 cycles
  • Switching frequency: <10 Hz
  • Response time: <20ms
  • Electromagnetic Compatibility: IEC 61326-3-1
  • Dielectric strength: ≥3000 VAC (between intrinsically safe and non‑intrinsically safe sides); ≥1500 VAC (between power supply and non‑intrinsically safe side)
  • Insulation resistance: ≥100 MΩ (input/output/power supply)
  • Operating temperature: -20°C to +60°C
  • Storage temperature: -40°C to +80°C
  • Dimensions: Width 17.8 mm × Height 110 mm × Depth 117 mm