Product Series
Please feel free to contact us!
We look forward to your call and inquiry!
Company Address
No. 90, Weisan Road, Industrial Zone, Wen County, Jiaozuo City, Henan Province
Service Hotline
Sales call
Technical Support
Email box
ASPGLK-G5122
- Commodity name: ASPGLK-G5122
- Input: Dry contact or NAMUR-type proximity switch
- Number of channels: One in, two out
- Output: Transistor collector output
- Power supply mode (both can be centralized power supply): 24VDC
Product Details
- Product Description
-
Product Introduction
Digital input and transistor output isolator: It isolates and transmits dry‑contact or NAMUR‑type proximity switch signals from the field to the control room, where they are processed as transistor outputs. Output and input logic can be configured via DIP switches to operate in either non‑inverting or inverting mode (non‑inverting by default). The device also allows you to enable or disable line‑fault monitoring (enabled by default, with LED blinking during a fault) and to configure a second output channel—either as a transistor output or as a fault‑alarm output. This product requires an independent power supply and features three‑terminal isolation between input, output, and power.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: ≤1W
- Input signal: dry contact or NAMUR-type proximity switch
- Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
- Open-circuit voltage: approximately 8.5 V
- Short-circuit current: approximately 8.5 mA
- Output signal: Transistor collector output (custom logic-level output available upon customer request)
- Drive current: ≤40 mA
- External voltage: <40 VDC
- Line fault: If the input current is ≤50 μA, the system detects an open‑circuit condition and deactivates the output relay; if the input current is ≥6.5 mA, a short‑circuit condition is detected, the output relay is de-energized, and the channel indicator flashes red.
- Switching frequency: <5 kHz
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥2500 VAC (between intrinsically safe side and non‑intrinsically safe side); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: 12.7 mm wide × 110 mm high × 118.9 mm deep
Product Introduction
Digital input and transistor output isolator: It isolates and transmits dry‑contact or NAMUR‑type proximity switch signals from the field to the control room, where they are processed as transistor outputs. Output and input logic can be configured via DIP switches to operate in either non‑inverting or inverting mode (non‑inverting by default). The device also allows you to enable or disable line‑fault monitoring (enabled by default, with LED blinking during a fault) and to configure a second output channel—either as a transistor output or as a fault‑alarm output. This product requires an independent power supply and features three‑terminal isolation between input, output, and power.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: ≤1W
- Input signal: dry contact or NAMUR-type proximity switch
- Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
- Open-circuit voltage: approximately 8.5 V
- Short-circuit current: approximately 8.5 mA
- Output signal: Transistor collector output (custom logic-level output available upon customer request)
- Drive current: ≤40 mA
- External voltage: <40 VDC
- Line fault: If the input current is ≤50 μA, the system detects an open‑circuit condition and deactivates the output relay; if the input current is ≥6.5 mA, a short‑circuit condition is detected, the output relay is de-energized, and the channel indicator flashes red.
- Switching frequency: <5 kHz
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥2500 VAC (between intrinsically safe side and non‑intrinsically safe side); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: 12.7 mm wide × 110 mm high × 118.9 mm deep
Keywords:
Please feel free to contact us!
Please provide your contact information and details, ensuring that all fields are filled in correctly. We will get in touch with you within 24 hours.