ASPGLK-G5D122
- Commodity name: ASPGLK-G5D122
- Input: Dry contact or NAMUR-type proximity switch
- Number of channels: Two in, two out
- Output: Transistor collector output
- Power supply mode (both can be centralized power supply): 24VDC
Product Details
- Product Description
-
Product Introduction
Digital input and transistor output isolator: It isolates and transmits dry‑contact or NAMUR‑type proximity switch signals from the field to the control room, where they are processed as transistor outputs. Output and input logic can be configured via DIP switches to operate in either non‑inverting or inverting mode (non‑inverting by default). The line‑fault monitoring function can also be enabled or disabled (enabled by default, with the LED flashing during a line fault), and a second output channel can be set to serve either as a transistor output or as a fault‑alarm output. This product requires an independent power supply and features three‑terminal isolation between input, output, and power.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: ≤1W
- Input signal: dry contact or NAMUR-type proximity switch
- Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
- Open-circuit voltage: approximately 8.5 V
- Short-circuit current: approximately 8.5 mA
- Output signal: Transistor collector output (custom logic-level output available upon customer request) Drive current: ≤40 mA
- External voltage: <40 VDC
- Line fault: If the input current is ≤50 μA, the system detects an open‑circuit condition and deactivates the output relay; if the input current is ≥6.5 mA, a short‑circuit condition is detected and the output relay is de-energized, while the channel indicator flashes red.
- Switching frequency: <5 kHz
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥2500 VAC (between intrinsically safe side and non‑intrinsically safe side); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: Width 12.7 mm × Height 110 mm × Depth 118.9 mm
Product Introduction
Digital input and transistor output isolator: It isolates and transmits dry‑contact or NAMUR‑type proximity switch signals from the field to the control room, where they are processed as transistor outputs. Output and input logic can be configured via DIP switches to operate in either non‑inverting or inverting mode (non‑inverting by default). The line‑fault monitoring function can also be enabled or disabled (enabled by default, with the LED flashing during a line fault), and a second output channel can be set to serve either as a transistor output or as a fault‑alarm output. This product requires an independent power supply and features three‑terminal isolation between input, output, and power.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: ≤1W
- Input signal: dry contact or NAMUR-type proximity switch
- Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
- Open-circuit voltage: approximately 8.5 V
- Short-circuit current: approximately 8.5 mA
- Output signal: Transistor collector output (custom logic-level output available upon customer request) Drive current: ≤40 mA
- External voltage: <40 VDC
- Line fault: If the input current is ≤50 μA, the system detects an open‑circuit condition and deactivates the output relay; if the input current is ≥6.5 mA, a short‑circuit condition is detected and the output relay is de-energized, while the channel indicator flashes red.
- Switching frequency: <5 kHz
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥2500 VAC (between intrinsically safe side and non‑intrinsically safe side); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: Width 12.7 mm × Height 110 mm × Depth 118.9 mm