  • Commodity name: ASFLK-F5D111
  • Input: Dry contact or NAMUR-type proximity switch
  • Number of channels: Two in, two out
  • Output: Relay contacts
  • Power supply mode (both can be centralized power supply): 24VDC

Phone:

Product Details

  • Product Description
  • Product Introduction

    It receives switch or proximity‑switch inputs from the field and, after isolation, outputs relay contact signals. Each channel can be independently configured for either in-phase or out-of-phase control of input and output, and it also features fault‑detection and alarm indication for the input circuitry. This product requires an independent power supply.

    Technical Specifications

    • Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
    • Current consumption: (with 24 V supply, when the output relay contacts are closed); ≤30 mA (one input, one output); ≤40 mA (one input, two outputs; two inputs, two outputs)
    • On-site side input: dry contact or NAMUR-type proximity switch; open-circuit voltage: ≈8 V; short-circuit current: ≈8 mA.
    • System-side output: relay contacts; response time: ≤20 ms; drive capability: 250 VAC, 5 A or 30 VDC, 5 A.
    • Load type: Resistive load
    • Input and output characteristics (configured for in-phase control): When the field switch is closed or the input loop current is ≥2.1 mA, the output relay closes and the channel’s yellow indicator light illuminates; when the field switch is open or the input loop current is ≤1.2 mA, the output relay opens and the channel’s yellow indicator light turns off.
    • Switch setting function:
    Status K1 (Output 1)
    K3 (Output 2)
    K2 (Output 1)
    K4 (Output 2)
    ON Input and output are inverted. Wired fault detection
    OFF Input and output are in phase. Wireless circuit fault detection
    • Electromagnetic Compatibility: Complies with IEC 61326-1 and IEC 61326-3-1.
    • Operating temperature: -20°C to +60°C
    • Dielectric Strength: Field side–System side, ≥1500 VAC; Power supply–System side, ≥500 VAC.
    • Insulation resistance: Field side–system side, ≥100 MΩ; power supply–system side, ≥100 MΩ.
    • Product weight: approximately 100 g
    • Applicable field devices: dry contacts or NAMUR-type proximity switches compliant with DIN 19234.

     

Product Introduction

It receives switch or proximity‑switch inputs from the field and, after isolation, outputs relay contact signals. Each channel can be independently configured for either in-phase or out-of-phase control of input and output, and it also features fault‑detection and alarm indication for the input circuitry. This product requires an independent power supply.

Technical Specifications

  • Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
  • Current consumption: (with 24 V supply, when the output relay contacts are closed); ≤30 mA (one input, one output); ≤40 mA (one input, two outputs; two inputs, two outputs)
  • On-site side input: dry contact or NAMUR-type proximity switch; open-circuit voltage: ≈8 V; short-circuit current: ≈8 mA.
  • System-side output: relay contacts; response time: ≤20 ms; drive capability: 250 VAC, 5 A or 30 VDC, 5 A.
  • Load type: Resistive load
  • Input and output characteristics (configured for in-phase control): When the field switch is closed or the input loop current is ≥2.1 mA, the output relay closes and the channel’s yellow indicator light illuminates; when the field switch is open or the input loop current is ≤1.2 mA, the output relay opens and the channel’s yellow indicator light turns off.
  • Switch setting function:
Status K1 (Output 1)
K3 (Output 2)
K2 (Output 1)
K4 (Output 2)
ON Input and output are inverted. Wired fault detection
OFF Input and output are in phase. Wireless circuit fault detection
  • Electromagnetic Compatibility: Complies with IEC 61326-1 and IEC 61326-3-1.
  • Operating temperature: -20°C to +60°C
  • Dielectric Strength: Field side–System side, ≥1500 VAC; Power supply–System side, ≥500 VAC.
  • Insulation resistance: Field side–system side, ≥100 MΩ; power supply–system side, ≥100 MΩ.
  • Product weight: approximately 100 g
  • Applicable field devices: dry contacts or NAMUR-type proximity switches compliant with DIN 19234.

 