ASGEXA-G5F11
- Commodity name: ASGEXA-G5F11
- Input: Dry contact or NAMUR-type proximity switch
- Number of channels: Four in, four out
- Output: Relay contacts
- Power supply mode (both can be centralized power supply): 24VDC
Product Details
- Product Description
-
Product Introduction
Digital input and relay output safety barrier: It isolates and outputs signals from dry contacts or NAMUR‑type proximity switches in the hazardous area to the safe area via isolated relay contacts. When ordering, please specify whether the four channels of inputs and outputs are in-phase or out-of-phase (default: in-phase). This product requires an independent power supply and features three‑terminal isolation between input, output, and power.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: 2.0 W
- Input signal: dry contact or NAMUR-type proximity switch
- Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
- Open-circuit voltage: approximately 8 V
- Short-circuit current: approximately 8 mA
- Output signal: relay contacts
- Allowable load: 125 VAC/0.5 A or 24 VDC/1 A
- Line fault: If the input current is ≤50 μA, a broken‑wire condition is detected and the output relay trips; if the input current is ≥6.5 mA, a short circuit is detected and the output relay trips, with the channel indicator flashing red.
- Switch life: >100,000 cycles
- Switching frequency: <10 Hz
- Response time: <20ms
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥3000 VAC (between intrinsically safe and non‑intrinsically safe sides); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: Width 17.8 mm × Height 110 mm × Depth 117 mm
- Application: Installed in hazardous areas, it can be connected to intrinsically safe equipment in Zones 0, 1, and 2; for gas groups IIA, IIB, and IIC; and for temperature classes T1 through T6.
Product Introduction
Digital input and relay output safety barrier: It isolates and outputs signals from dry contacts or NAMUR‑type proximity switches in the hazardous area to the safe area via isolated relay contacts. When ordering, please specify whether the four channels of inputs and outputs are in-phase or out-of-phase (default: in-phase). This product requires an independent power supply and features three‑terminal isolation between input, output, and power.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: 2.0 W
- Input signal: dry contact or NAMUR-type proximity switch
- Switching characteristics: When the input current exceeds 2.1 mA, the output relay closes and the channel indicator light remains steadily illuminated in yellow; when the input current falls below 1.2 mA, the output relay opens and the channel indicator light turns off.
- Open-circuit voltage: approximately 8 V
- Short-circuit current: approximately 8 mA
- Output signal: relay contacts
- Allowable load: 125 VAC/0.5 A or 24 VDC/1 A
- Line fault: If the input current is ≤50 μA, a broken‑wire condition is detected and the output relay trips; if the input current is ≥6.5 mA, a short circuit is detected and the output relay trips, with the channel indicator flashing red.
- Switch life: >100,000 cycles
- Switching frequency: <10 Hz
- Response time: <20ms
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥3000 VAC (between intrinsically safe and non‑intrinsically safe sides); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: Width 17.8 mm × Height 110 mm × Depth 117 mm
- Application: Installed in hazardous areas, it can be connected to intrinsically safe equipment in Zones 0, 1, and 2; for gas groups IIA, IIB, and IIC; and for temperature classes T1 through T6.