Product Series
Please feel free to contact us!
We look forward to your call and inquiry!
Company Address
No. 90, Weisan Road, Industrial Zone, Wen County, Jiaozuo City, Henan Province
Service Hotline
Sales call
Technical Support
Email box
ASGEXA-G31
- Commodity name: ASGEXA-G31
- Input: Direct current signal
- Number of channels: One in, one out
- Output: 4–20 mA
- Power supply mode (both can be centralized power supply): 24VDC
- HART transparent transmission function: Not supported
Product Details
- Product Description
-
Product Introduction
The current‑sensing safety barrier isolates and converts signals from 2‑wire or 3‑wire transmitters or current sources in the hazardous area into a safe‑area output of 4–20 mA. This device requires an independent power supply and features three‑terminal isolation between input, output, and power. It includes built-in online fault self‑diagnosis and allows configuration—via PC or a handheld programmer—of signal types and the output behavior in the event of a signal fault.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: 1.3 W (24 V, single-channel full-load output); 1.8 W (24 V, dual-channel full-load output)
- Input signal: DC current signal
- Input impedance: ≤100 Ω
- Distribution voltage: Open-circuit voltage ≤ 26 V; at 20 mA, output voltage ≥ 16 V. Output signal: 4–20 mA.
- Allowable load: RL ≤ 550 Ω
- Conversion accuracy: 0.1% F.S. (25°C ± 2°C)
- Temperature Drift: 40 ppm/°C
- Response time: ≤500 ms
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥2500 VAC (between intrinsically safe side and non‑intrinsically safe side); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: Width 12.7 mm × Height 110 mm × Depth 118.9 mm
- Output status: Unless otherwise specified by the user, the output will track changes in the input signal across the full‑scale range, regardless of any fault conditions in the input. (Exception: when the 4–20 mA line is open, the output will be 0 V or 0 mA.) However, the output shall not exceed 110% of the upper limit of the output range. For example, with a 0–20 mA output, the minimum output may be 0 mA, and the maximum shall not exceed 22 mA.
- Application: Installed in a safe area, it can be connected to intrinsically safe equipment in Zones 0, 1, and 2; for gas groups IIA, IIB, and IIC; and for temperature classes T1 through T6.
Product Introduction
The current‑sensing safety barrier isolates and converts signals from 2‑wire or 3‑wire transmitters or current sources in the hazardous area into a safe‑area output of 4–20 mA. This device requires an independent power supply and features three‑terminal isolation between input, output, and power. It includes built-in online fault self‑diagnosis and allows configuration—via PC or a handheld programmer—of signal types and the output behavior in the event of a signal fault.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: 1.3 W (24 V, single-channel full-load output); 1.8 W (24 V, dual-channel full-load output)
- Input signal: DC current signal
- Input impedance: ≤100 Ω
- Distribution voltage: Open-circuit voltage ≤ 26 V; at 20 mA, output voltage ≥ 16 V. Output signal: 4–20 mA.
- Allowable load: RL ≤ 550 Ω
- Conversion accuracy: 0.1% F.S. (25°C ± 2°C)
- Temperature Drift: 40 ppm/°C
- Response time: ≤500 ms
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric strength: ≥2500 VAC (between intrinsically safe side and non‑intrinsically safe side); ≥1500 VAC (between power supply and non‑intrinsically safe side)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: Width 12.7 mm × Height 110 mm × Depth 118.9 mm
- Output status: Unless otherwise specified by the user, the output will track changes in the input signal across the full‑scale range, regardless of any fault conditions in the input. (Exception: when the 4–20 mA line is open, the output will be 0 V or 0 mA.) However, the output shall not exceed 110% of the upper limit of the output range. For example, with a 0–20 mA output, the minimum output may be 0 mA, and the maximum shall not exceed 22 mA.
- Application: Installed in a safe area, it can be connected to intrinsically safe equipment in Zones 0, 1, and 2; for gas groups IIA, IIB, and IIC; and for temperature classes T1 through T6.
Keywords:
Please feel free to contact us!
Please provide your contact information and details, ensuring that all fields are filled in correctly. We will get in touch with you within 24 hours.