  • Commodity name: ASFGLB-FM11D
  • Input: 4–20 mA
  • Number of channels: One in, one out
  • Output: 4–20 mA
  • Power supply mode (both can be centralized power supply): 24VDC
  • HART transparent transmission function: Not supported

Phone:

Product Details

  • Product Description
  • Product Introduction

    The current‑sensing safety barrier isolates and converts 2‑wire or 3‑wire transmitter or current‑source signals from the hazardous area into a safe‑area signal (4–20 mA). This product requires an independent power supply and features three‑terminal isolation between input, output, and power. It includes built-in online fault self‑diagnosis and allows configuration of the temperature range, signal type, and output behavior in case of signal failure via a PC or a handheld programmer.

    Technical Specifications

    • Supply voltage: 18–32 VDC, with reverse polarity protection.
    • Supply current: (with 24 V supply and 20 mA output) ≤ 55 mA
    • On-site side output: 4–20 mA; Load resistance: 0–1000 Ω
    • System-side input: 4–20 mA; input impedance: ≤50 Ω
    • Output accuracy: 0.1% F.S.
    • Temperature drift: 0.005% F.S./°C
    • Response time: 2 ms to reach 90% of the final value
    • Electromagnetic Compatibility: Complies with IEC 61326-1 and IEC 61326-3-1.
    • Operating ambient temperature: -20°C to +60°C
    • Dielectric Strength: Field side–System side, ≥1500 VAC; Power supply–System side, ≥500 VAC.
    • Insulation resistance: Field side–system side, ≥100 MΩ; Power supply–system side, ≥100 MΩ.
    • Product weight: approximately 100 g
    • Applicable field devices: valve positioners, electrical transducers, etc.

Product Introduction

The current‑sensing safety barrier isolates and converts 2‑wire or 3‑wire transmitter or current‑source signals from the hazardous area into a safe‑area signal (4–20 mA). This product requires an independent power supply and features three‑terminal isolation between input, output, and power. It includes built-in online fault self‑diagnosis and allows configuration of the temperature range, signal type, and output behavior in case of signal failure via a PC or a handheld programmer.

Technical Specifications

  • Supply voltage: 18–32 VDC, with reverse polarity protection.
  • Supply current: (with 24 V supply and 20 mA output) ≤ 55 mA
  • On-site side output: 4–20 mA; Load resistance: 0–1000 Ω
  • System-side input: 4–20 mA; input impedance: ≤50 Ω
  • Output accuracy: 0.1% F.S.
  • Temperature drift: 0.005% F.S./°C
  • Response time: 2 ms to reach 90% of the final value
  • Electromagnetic Compatibility: Complies with IEC 61326-1 and IEC 61326-3-1.
  • Operating ambient temperature: -20°C to +60°C
  • Dielectric Strength: Field side–System side, ≥1500 VAC; Power supply–System side, ≥500 VAC.
  • Insulation resistance: Field side–system side, ≥100 MΩ; Power supply–system side, ≥100 MΩ.
  • Product weight: approximately 100 g
  • Applicable field devices: valve positioners, electrical transducers, etc.