ASPFC-G11D
- Commodity name: ASPFC-G11D
- Input: Frequency pulse signal
- Number of channels: Two in, two out
- Output: With/without power, 0–4 to 20 mA,0–10 mA,0/1–5 V,0–10 V
- Power supply mode (both can be centralized power supply): 24VDC
Product Details
- Product Description
-
Product Introduction
Frequency transmitter: The input frequency pulse signal is isolated and converted into a current or voltage output. This product requires an independent power supply, with three-terminal isolation between the input, output, and power supply. It features built-in online fault self‑diagnosis and allows configuration—via PC or a handheld programmer—of the measurement range for the frequency pulse signal and the output mode in case of signal failure.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: 85 VAC to 265 VAC (90 VDC to 360 VDC); ≤0.8 W (24 V, single-channel full-load output); ≤1.3 W (24 V, dual-channel full-load output); ≤1.3 W (220 V, single-channel full-load output); ≤2.5 W (220 V, dual-channel full-load output).
- Input signal: frequency pulse signal
- Frequency range: 0.1 Hz to 100 kHz
- Pulse width: >5 μs
- Input impedance: ≥10 kΩ
- Signal Trigger: Low Level: 0 V to 2 V; High Level: 4 V to 30 V (customizable upon customer request)
- Distribution voltage: 24 VDC; at 20 mA, the output voltage is ≥22 V (default); 12 VDC; at 20 mA, the output voltage is ≥11 V.
- Output signals: Current: active/passive 0–4 to 20 mA, 0–10 mA; Voltage: 0–1 to 5 V, 0–10 V.
- Permissible load: 0–4 mA: RL ≤ 550 Ω; 0–10 mA: RL ≤ 1.1 kΩ; 0–1 V: RL ≥ 1 MΩ; 0–10 V: RL ≥ 2 MΩ; passive: RL < [(U − 3) / 0.02] Ω, where U is the loop voltage.
- Conversion accuracy: 0.1% F.S. (25°C ± 2°C)
- Temperature Drift: 40 ppm/°C
- Response time: ≤500 ms
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric Strength: ≥2500 VAC (between input, output, and power supply)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: 12.7 mm wide × 110 mm high × 118.9 mm deep
- Output status: If the input is open‑circuit, the LED flashes; if the input exceeds the measurement range, the LED remains steadily lit. When the input is open‑circuit or out of range, the output current can be set within the 0–22 mA range (default: follows the input).
Product Introduction
Frequency transmitter: The input frequency pulse signal is isolated and converted into a current or voltage output. This product requires an independent power supply, with three-terminal isolation between the input, output, and power supply. It features built-in online fault self‑diagnosis and allows configuration—via PC or a handheld programmer—of the measurement range for the frequency pulse signal and the output mode in case of signal failure.
Technical Specifications
- Power Supply: 18 VDC to 32 VDC, with reverse polarity protection.
- Operating power consumption: 85 VAC to 265 VAC (90 VDC to 360 VDC); ≤0.8 W (24 V, single-channel full-load output); ≤1.3 W (24 V, dual-channel full-load output); ≤1.3 W (220 V, single-channel full-load output); ≤2.5 W (220 V, dual-channel full-load output).
- Input signal: frequency pulse signal
- Frequency range: 0.1 Hz to 100 kHz
- Pulse width: >5 μs
- Input impedance: ≥10 kΩ
- Signal Trigger: Low Level: 0 V to 2 V; High Level: 4 V to 30 V (customizable upon customer request)
- Distribution voltage: 24 VDC; at 20 mA, the output voltage is ≥22 V (default); 12 VDC; at 20 mA, the output voltage is ≥11 V.
- Output signals: Current: active/passive 0–4 to 20 mA, 0–10 mA; Voltage: 0–1 to 5 V, 0–10 V.
- Permissible load: 0–4 mA: RL ≤ 550 Ω; 0–10 mA: RL ≤ 1.1 kΩ; 0–1 V: RL ≥ 1 MΩ; 0–10 V: RL ≥ 2 MΩ; passive: RL < [(U − 3) / 0.02] Ω, where U is the loop voltage.
- Conversion accuracy: 0.1% F.S. (25°C ± 2°C)
- Temperature Drift: 40 ppm/°C
- Response time: ≤500 ms
- Electromagnetic Compatibility: IEC 61326-3-1
- Dielectric Strength: ≥2500 VAC (between input, output, and power supply)
- Insulation resistance: ≥100 MΩ (input/output/power supply)
- Operating temperature: -20°C to +60°C
- Storage temperature: -40°C to +80°C
- Dimensions: 12.7 mm wide × 110 mm high × 118.9 mm deep
- Output status: If the input is open‑circuit, the LED flashes; if the input exceeds the measurement range, the LED remains steadily lit. When the input is open‑circuit or out of range, the output current can be set within the 0–22 mA range (default: follows the input).